- Your one stop shop for KNX devices in the USA 🇺🇸
- (+1) 786 956 6821
- support@knxsupply.com
- Store Location
- Sign in or Register
- Home
-
Categories
- System Devices
- Switching/Shutter Actuators
- Dimming Actuators
- HVAC
- Binary Inputs
- Keypads
- Gateways
- Enclosures and Boxes
- Occupancy Sensors
- Visualization Systems and Touch Panels
- Weather Sensors
- Drivers and ECGs
- Special Sensors
- HVAC
- Accessories
- Cable
- Expert Picks
- KNX Certified Training
- Newest Products
- Best Selling Products
Brands
- Articles
- Contact Us
- Home
- All Collections
- Products
Products
Information
Building automation and security technology combined flawlessly:
The world's first KNX connection (plug-in) for networking products from the Axis Communications company.
Note:
The plug-in can only be used on network devices from Axis Communications with ACAP support.
Features:
• Support of Axis network cameras
• Support of Axis WLAN cameras *
• Support of Axis D2050 -VE Network Radar Detector
• Support of Axis door stations
• Support of Axis network loudspeakers
• 30 group objects for sending from KNX to the Axis camera (1 bit)
• 30 group objects for sending from the Axis camera to KNX (variable bit length)
• Control of actions on the camera
Information
Integrate the innovative single-room control Fonterra Smart Control by viega via the gateway SMART CONNECT KNX viega into the KNX system.
Features:
• Support of 5 base stations each with up to 8 room temperature controllers and 12 outlets
• Room temperature control
• Switching between heating and cooling mode
• Power level control
• Absence control
• System information such as error messages, actual temperature or updates from viega
• Simple integration in KNX (can be completely configured via ETS)
• Extensions via firmware updates
If you wish to use the SMART CONNECT KNX viega, you must use Fonterra Smart Control for Fonterra surface temperature
regulating systems in Version 3 or higher with firmware version 2.8-4.43 or higher, supplied by Viega GmbH & Co. KG.
- Power supply: via KNX Bus line, 20VDC
- Rated voltage: 120V AC +10%/-15%, 50/60 Hz
- Rated current:
- 2-channel: 2x1.3A@cosФ=1.0
- 1-channel: 1x2.2A@cosФ=1.0
- N-system DIN-rail mounted device, width:4MU(1MU=18mm)
- Load output:Lamp type2 channels1 channel
Incandescent lamps 150 W250 WLow voltage halogen lamps
with magnetic transformers
120 VA200 VADimmable LED <= 50 VA<=50 VA
Intesis INKNXUNI001I000 allows monitoring and control of Air Conditioners from KNX installations.
- Compatible with most AC units with an IR receiver.
- Great flexibility of integration into your KNX projects.
- Configuration is made directly from ETS, the database of the device comes with a complete set of communication objects allowing, from a simple and quick integration using the basic objects, allowing a simple and quick integration.
Check compatible AC units in the description.
- Thermoplastic material, halogen-free
- Dimensional stability: -5 … 60 ºC
- Compliance:
-2014/35/EU (low voltage directive)
-2011/65/EU (RoHS directive)
-Standards: UNE EN 60670-1
- Thermoplastic material, halogen-free
- Dimensional stability: -5 … 60 ºC
- Compliance:
-2014/35/EU (low voltage directive)
-2011/65/EU (RoHS directive)
-Standards: UNE EN 60670-1
- The DALI push-button input 4-fold flush-mounted 141/71 is a binary input device for insertion into a flush-mounted box.
- The device is powered via the connected DALI cable
- The device offers 4 input channels for potential-free contacts
- Installation switches or installation push-buttons can be connected. The required voltage is supplied by the DALI push-button input 4-fold (no additional voltage source required).
- Triggered by the connected push-buttons or switches, the DALI push-button input 4-fold sends telegrams via the DALI line to a central DALI controller.
- The push button interface is a binary input and output device for installation in in-wall boxes (Æ 60 mm, depth: 40 mm).
- Each of the two channels may be used either as an input for potential-free switch / push button contacts or as an output for control of a light emitting diode (LED).
- The required scanning / control voltage is provided by the push button interface (requires no additional power supply).
- For example, up to 2 switches/push buttons with one potential-free contact each or one 2-fold push button with two potential-free contacts may be connected to a push button interface.
- The connection is carried out via a cable set which is permanently connected to the push button interface.
- The connecting cables between switches/push buttons and the push button interface may be extended up to 10 m. It must be ensured that twisted cable pairs are used.
- Commands can be given to actuators via the connected switches/push buttons, e.g. for defined switching on/off, for dimming fluorescent lamps or for raising/lowering venetian blinds and adjusting the louvres.
- Each channel, which is configured as an output, can drive an output current of up to 2mA for controlling a light emitting diode (LED).
- With the ETS the application program is selected, its parameters and addresses are assigned appropriately, and downloaded to the push button interface.
- The push button interface is a binary input and output devices for installation in in-wall boxes (Æ60 mm, depth: 40 mm).
- Each of the four channels may be used either as an input for potential-free switch / push button contacts or as an output for control of a light emitting diode (LED).
- The required scanning / control voltage is provided by the push button interface (requires no additional power supply).
Presence / Motion detector
- The detector senses the presence of a person or that there is no longer anyone in its detection area.
- The detector signal can be analyzed via two separate communication channels, termed motion detector and presence detector.
- The detection range is identical for all channels. Each channel can be locked individually via objects.
HVAC detector
- The detector has an additional control output for HVAC applications.
- For example, this function can switch systems that are used for heating, ventilating and climate control (HVAC) of the room from “Energy saving mode” in an unused room to “Comfort mode” in an occupied room and back to “Energy saving mode”, when the room is again unoccupied.
- Functionality of the Presence detector / Motion detector / HVAC-detector
- For each detector channel 4 communication objects are available, in sum 12 different communication objects.
- It is possible to send one or two KNX telegrams at the beginning and at the end of a detected presence, according to configuration.
- The values of the communication objects are configured for each functional block (motion detector, presence detector, HVAC-detector) via corresponding parameters.
Presence detector with brightness sensor for detection of motion and presence for ceiling mounting
- Contrast measurement of brightness
- Presence motion detection up to Ø8 m
- Flush mounted installation in ceilings with wall box or clamps
- Integrated IR receiver for IR remote control
Functions with commission with ETS
- Three independent output channels with four commands each in case of motion detection
- Integrated 2-level light controller (switching)
- Integrated constant light level controller for up to five lighting groups including
- Usage of motion detector as standalone mode or extension mode to cover wider areas
- Independent output channel for HVAC applications
Characteristics
- These presence detectors are equipped with an integrated brightness sensor and HVAC sensors that use multiple calibration methods so that they can be adjusted at the particular installation location.
- The maximum detection area is 64 m² for presence and 400 m² for motion.
- The presence detectors capture brightness, humidity, temperature, brightness and CO2 and thus control not only the illumination systems but also ventilation and heating systems.
- Communication is conducted via KNX. All types are designed for mounting on the ceiling.
Characteristics
- These presence detectors are equipped with an integrated brightness sensor and HVAC sensors that use multiple calibration methods so that they can be adjusted at the particular installation location.
- The maximum detection area is 64 m² for presence and 400 m² for motion.
- The presence detectors capture brightness, humidity, temperature, brightness and CO2 and thus control not only the illumination systems but also ventilation and heating systems.
- Communication is conducted via KNX. All types are designed for mounting on the ceiling.
Characteristics
- These presence detectors are equipped with an integrated brightness sensor and HVAC sensors that use multiple calibration methods so that they can be adjusted at the particular installation location.
- The maximum detection area is 64 m² for presence and 400 m² for motion.
- The presence detectors capture brightness, humidity, temperature, brightness and CO2 and thus control not only the illumination systems but also ventilation and heating systems.
- Communication is conducted via KNX. All types are designed for mounting on the ceiling.
Characteristics
- Actively emitted by the ultrasound sensor (US), ultrasound waves (40 kHz) propagate around the rest of the room.
- They envelop objects that are in the room and penetrate into all corners.
- This means that the ultrasound sensor (US) can even detect movements when there is no line-of-sight contact between it and the person.
- This presence detector is equipped with an integrated brightness and temperature sensor.
- The maximum detection area is 28 m² for presence and 79 m² for motion.
- The presence detector captures brightness and temperature data and thus controls not only the illumination systems but also ventilation and heating systems.
- Communication is conducted via KNX. The presence detector is designed for installation in the ceiling.
Presence detector with brightness sensor for detection of motion and presence for ceiling mounting
- Contrast measurement of brightness
- Presence motion detection up to Ø8 m
- Flush mounted installation in ceilings with wall box or clamps
- Integrated IR receiver for IR remote control
Functions with commission with ETS
- Three independent output channels with four commands each in case of motion detection
- Integrated 2-level light controller (switching)
- Integrated constant light level controller for up to five lighting groups including
- Usage of motion detector as standalone mode or extension mode to cover wider areas
- Independent output channel for HVAC applications
Accessory cables/connector for KNX room controller, serie VERSO, Ref. E-KUSB1
USB extension cable for IDDERO VERSO
USB 2.0 cable, micro B/M - A/F
The MDT Glass Push-button releases KNX telegrams after touching the sensor areas on top, 1 or 2 button operation can be parameterized.
Wall mount box for DIVUS CIRCLE small and DIVUS CIRCLE small +
Wall mounted temperature probe with GLASS front finish, available in white or black.
The TS-GLASS temperature probe allows measurement of ambient temperature of the surrounding air, for example for HVAC regulation within a room.
It is recommended to install the probe in a location away from sources of heat or cold that could introduce errors in temperature measurements.
Compatible with Iddero touch panels (HC3-KNX, HC3L-KNX, Iddero VERSO family) and with Iddero Home Server / Iddero Home Server 3.