• Your one stop shop for KNX devices in the USA 🇺🇸
Filter
Availability
Price
$
$
Manufacturer
+ Show more - Show less
Product type
+ Show more - Show less

Products

Filter
Showing 501 - 520 of 526 items
SMART CONNECT KNX SONOS
30%

Information

Building automation and security technology combined flawlessly:

The world's first KNX connection (plug-in) for networking products from the Axis Communications company.

Note:

The plug-in can only be used on network devices from Axis Communications with ACAP support.

Features:

• Support of Axis network cameras

• Support of Axis WLAN cameras *

• Support of Axis D2050 -VE Network Radar Detector

• Support of Axis door stations

• Support of Axis network loudspeakers

• 30 group objects for sending from KNX to the Axis camera (1 bit)

• 30 group objects for sending from the Axis camera to KNX (variable bit length)

• Control of actions on the camera



SMART CONNECT KNX VIEGA
30%

Information

Integrate the innovative single-room control Fonterra Smart Control by viega via the gateway SMART CONNECT KNX viega into the KNX system.

Features:

• Support of 5 base stations each with up to 8 room temperature controllers and 12 outlets

• Room temperature control

• Switching between heating and cooling mode

• Power level control

• Absence control

• System information such as error messages, actual temperature or updates from viega

• Simple integration in KNX (can be completely configured via ETS)

• Extensions via firmware updates

If you wish to use the SMART CONNECT KNX viega, you must use Fonterra Smart Control for Fonterra surface temperature

regulating systems in Version 3 or higher with firmware version 2.8-4.43 or higher, supplied by Viega GmbH & Co. KG.

Universal Dimmer 2-Fold
62%
  • Power supply: via KNX Bus line, 20VDC
  • Rated voltage: 120V AC +10%/-15%, 50/60 Hz
  • Rated current:
    • 2-channel: 2x1.3A@cosФ=1.0
    • 1-channel: 1x2.2A@cosФ=1.0
  • N-system DIN-rail mounted device, width:4MU(1MU=18mm)
  • Load output:
    Lamp type
    2 channels
    1 channel
    Incandescent lamps
    150 W
    250 W

    Low voltage halogen lamps

    with magnetic transformers

    120 VA
    200 VA
    Dimmable LED
    <= 50 VA
    <=50 VA
Universal IR Air Conditioner to KNX interface - 1 UNIT
18%

Intesis INKNXUNI001I000 allows monitoring and control of Air Conditioners from KNX installations.

  • Compatible with most AC units with an IR receiver.
  • Great flexibility of integration into your KNX projects.
  • Configuration is made directly from ETS, the database of the device comes with a complete set of communication objects allowing, from a simple and quick integration using the basic objects, allowing a simple and quick integration.

Check compatible AC units in the description.

Universal wall-mount box for drywall / plasterboard, Ø 68 x 46 mm
50%
  • Thermoplastic material, halogen-free
  • Dimensional stability: -5 … 60 ºC
  • Compliance:

-2014/35/EU (low voltage directive)

-2011/65/EU (RoHS directive)

-Standards: UNE EN 60670-1

Universal wall-mount box for solid walls, 65 x 65 x 40 mm
50%
  • Thermoplastic material, halogen-free
  • Dimensional stability: -5 … 60 ºC
  • Compliance:

-2014/35/EU (low voltage directive)

-2011/65/EU (RoHS directive)

-Standards: UNE EN 60670-1

UP 141/71 - DALI Push button interface 4fold
62%
  • The DALI push-button input 4-fold flush-mounted 141/71 is a binary input device for insertion into a flush-mounted box.
  • The device is powered via the connected DALI cable
  • The device offers 4 input channels for potential-free contacts
  • Installation switches or installation push-buttons can be connected. The required voltage is supplied by the DALI push-button input 4-fold (no additional voltage source required).
  • Triggered by the connected push-buttons or switches, the DALI push-button input 4-fold sends telegrams via the DALI line to a central DALI controller. 
UP 220/21 - Pushbutton interface 2 x potential-free contact, output for LED control
62%
  • The push button interface is a binary input and output device for installation in in-wall boxes (Æ 60 mm, depth: 40 mm).
  • Each of the two channels may be used either as an input for potential-free switch / push button contacts or as an output for control of a light emitting diode (LED).
  • The required scanning / control voltage is provided by the push button interface (requires no additional power supply).
  • For example, up to 2 switches/push buttons with one potential-free contact each or one 2-fold push button with two potential-free contacts may be connected to a push button interface.
  • The connection is carried out via a cable set which is permanently connected to the push button interface.
  • The connecting cables between switches/push buttons and the push button interface may be extended up to 10 m. It must be ensured that twisted cable pairs are used.
  • Commands can be given to actuators via the connected switches/push buttons, e.g. for defined switching on/off, for dimming fluorescent lamps or for raising/lowering venetian blinds and adjusting the louvres.
  • Each channel, which is configured as an output, can drive an output current of up to 2mA for controlling a light emitting diode (LED).
  • With the ETS the application program is selected, its parameters and addresses are assigned appropriately, and downloaded to the push button interface.
UP 220/21 - Pushbutton interface 2 x potential-free contact, output for LED control
62%
  • The push button interface is a binary input and output devices for installation in in-wall boxes (Æ60 mm, depth: 40 mm).
  • Each of the four channels may be used either as an input for potential-free switch / push button contacts or as an output for control of a light emitting diode (LED).
  • The required scanning / control voltage is provided by the push button interface (requires no additional power supply).
UP 255D21 - Brightness Sensor with constant light level controller
62%

Presence / Motion detector

  • The detector senses the presence of a person or that there is no longer anyone in its detection area.
  • The detector signal can be analyzed via two separate communication channels, termed motion detector and presence detector.
  • The detection range is identical for all channels. Each channel can be locked individually via objects.

HVAC detector

  • The detector has an additional control output for HVAC applications.
  • For example, this function can switch systems that are used for heating, ventilating and climate control (HVAC) of the room from “Energy saving mode” in an unused room to “Comfort mode” in an occupied room and back to “Energy saving mode”, when the room is again unoccupied.
  • Functionality of the Presence detector / Motion detector / HVAC-detector
  • For each detector channel 4 communication objects are available, in sum 12 different communication objects. 
  • It is possible to send one or two KNX telegrams at the beginning and at the end of a detected presence, according to configuration. 
  • The values of the communication objects are configured for each functional block (motion detector, presence detector, HVAC-detector) via corresponding parameters.
UP 258D12 - Presence Detector with brightness sensor
62%

Presence detector with brightness sensor for detection of motion and presence for ceiling mounting

  • Contrast measurement of brightness
  • Presence motion detection up to Ø8 m
  • Flush mounted installation in ceilings with wall box or clamps
  • Integrated IR receiver for IR remote control

Functions with commission with ETS

  • Three independent output channels with four commands each in case of motion detection
  • Integrated 2-level light controller (switching)
  • Integrated constant light level controller for up to five lighting groups including
  • Usage of motion detector as standalone mode or extension mode to cover wider areas
  • Independent output channel for HVAC applications
UP 258D31 - Presence Detector WIDE with temperature measurement
62%

Characteristics

  • These presence detectors are equipped with an integrated brightness sensor and HVAC sensors that use multiple calibration methods so that they can be adjusted at the particular installation location.
  • The maximum detection area is 64 m² for presence and 400 m² for motion.
  • The presence detectors capture brightness, humidity, temperature, brightness and CO2 and thus control not only the illumination systems but also ventilation and heating systems.
  • Communication is conducted via KNX. All types are designed for mounting on the ceiling.
UP 258D41 - Presence Detector WIDE pro with temperature and relative humidity measurement
62%

Characteristics

  • These presence detectors are equipped with an integrated brightness sensor and HVAC sensors that use multiple calibration methods so that they can be adjusted at the particular installation location.
  • The maximum detection area is 64 m² for presence and 400 m² for motion.
  • The presence detectors capture brightness, humidity, temperature, brightness and CO2 and thus control not only the illumination systems but also ventilation and heating systems.
  • Communication is conducted via KNX. All types are designed for mounting on the ceiling.
UP 258D51 - Presence Detector WIDE multi with temperature, humidity and CO2 measurement
62%

Characteristics

  • These presence detectors are equipped with an integrated brightness sensor and HVAC sensors that use multiple calibration methods so that they can be adjusted at the particular installation location.
  • The maximum detection area is 64 m² for presence and 400 m² for motion.
  • The presence detectors capture brightness, humidity, temperature, brightness and CO2 and thus control not only the illumination systems but also ventilation and heating systems.
  • Communication is conducted via KNX. All types are designed for mounting on the ceiling.
UP 258D61 - Presence Detector WIDE DualTech with temperature measurement
62%

Characteristics

  • Actively  emitted by the ultrasound sensor (US), ultrasound waves (40 kHz) propagate around the rest of the room. 
  • They envelop objects that are in the room and penetrate into all corners.
  • This means that the ultrasound sensor (US) can even detect movements when there is no line-of-sight contact between it and the person.
  • This presence detector is equipped with an integrated brightness and temperature sensor.
  • The maximum detection area is 28 m² for presence and 79 m² for motion.
  • The presence detector captures brightness and temperature data and thus controls not only the illumination systems but also ventilation and heating systems.
  • Communication is conducted via KNX. The presence detector is designed for installation in the ceiling.
UP 258E22 - Presence Detector / Motion detector with constant light level control
62%

Presence detector with brightness sensor for detection of motion and presence for ceiling mounting

  • Contrast measurement of brightness
  • Presence motion detection up to Ø8 m
  • Flush mounted installation in ceilings with wall box or clamps
  • Integrated IR receiver for IR remote control

Functions with commission with ETS

  • Three independent output channels with four commands each in case of motion detection
  • Integrated 2-level light controller (switching)
  • Integrated constant light level controller for up to five lighting groups including
  • Usage of motion detector as standalone mode or extension mode to cover wider areas
  • Independent output channel for HVAC applications
USB 2.0 cable, micro B/M - A/F
50%

Accessory cables/connector for KNX room controller, serie VERSO, Ref. E-KUSB1

USB extension cable for IDDERO VERSO

USB 2.0 cable, micro B/M - A/F


Version neutral with 4 sensor surfaces.
45%

The MDT Glass Push-button releases KNX telegrams after touching the sensor areas on top, 1 or 2 button operation can be parameterized.

Wall mount box for DIVUS CIRCLE small and DIVUS CIRCLE small +

Wall mounted temperature probe, GLASS black
50%

Wall mounted temperature probe with GLASS front finish, available in white or black.

The TS-GLASS temperature probe allows measurement of ambient temperature of the surrounding air, for example for HVAC regulation within a room.

It is recommended to install the probe in a location away from sources of heat or cold that could introduce errors in temperature measurements.

Compatible with Iddero touch panels (HC3-KNX, HC3L-KNX, Iddero VERSO family) and with Iddero Home Server / Iddero Home Server 3.