Motion Detector with 2 sensors and temperature sensor.

For wall mounting at 2.2 m.

Suitable for 55 mm switch ranges.

The MDT Mini Presence Detector with 1 pyro sensor and a high-resolution lens detect even the smallest movements.

For ceiling installation in 35 mm Kaiser installation box.

Version for hollow wall mounting.

Integrated Bus coupler.

KNX Secure.

Version for hollow wall mounting.

Integrated Bus coupler.

KNX Secure.

The MDT Glass Presence Detector is available in two versions.

3 pyro sensors and a high-resolution lens detect even the smallest movements.

The MDT Glass Presence Detector is available in two versions.

3 pyro sensors and a high-resolution lens detect even the smallest movements.

KNX Combi-Presence Detector with constant light control and Air-quality signal light function.

KNX Combi-Presence Detector with constant light control and Air-quality signal light function.

The Brightness Sensor / -Controller with constant level light intensity is suited for ceiling installation in 35 mm Kaiser installation box.

UP 258D12 - Presence Detector with brightness sensor
62%

Presence detector with brightness sensor for detection of motion and presence for ceiling mounting

  • Contrast measurement of brightness
  • Presence motion detection up to Ø8 m
  • Flush mounted installation in ceilings with wall box or clamps
  • Integrated IR receiver for IR remote control

Functions with commission with ETS

  • Three independent output channels with four commands each in case of motion detection
  • Integrated 2-level light controller (switching)
  • Integrated constant light level controller for up to five lighting groups including
  • Usage of motion detector as standalone mode or extension mode to cover wider areas
  • Independent output channel for HVAC applications
UP 258E22 - Presence Detector / Motion detector with constant light level control
62%

Presence detector with brightness sensor for detection of motion and presence for ceiling mounting

  • Contrast measurement of brightness
  • Presence motion detection up to Ø8 m
  • Flush mounted installation in ceilings with wall box or clamps
  • Integrated IR receiver for IR remote control

Functions with commission with ETS

  • Three independent output channels with four commands each in case of motion detection
  • Integrated 2-level light controller (switching)
  • Integrated constant light level controller for up to five lighting groups including
  • Usage of motion detector as standalone mode or extension mode to cover wider areas
  • Independent output channel for HVAC applications
UP 258D61 - Presence Detector WIDE DualTech with temperature measurement
62%

Characteristics

  • Actively  emitted by the ultrasound sensor (US), ultrasound waves (40 kHz) propagate around the rest of the room. 
  • They envelop objects that are in the room and penetrate into all corners.
  • This means that the ultrasound sensor (US) can even detect movements when there is no line-of-sight contact between it and the person.
  • This presence detector is equipped with an integrated brightness and temperature sensor.
  • The maximum detection area is 28 m² for presence and 79 m² for motion.
  • The presence detector captures brightness and temperature data and thus controls not only the illumination systems but also ventilation and heating systems.
  • Communication is conducted via KNX. The presence detector is designed for installation in the ceiling.
UP 258D31 - Presence Detector WIDE with temperature measurement
62%

Characteristics

  • These presence detectors are equipped with an integrated brightness sensor and HVAC sensors that use multiple calibration methods so that they can be adjusted at the particular installation location.
  • The maximum detection area is 64 m² for presence and 400 m² for motion.
  • The presence detectors capture brightness, humidity, temperature, brightness and CO2 and thus control not only the illumination systems but also ventilation and heating systems.
  • Communication is conducted via KNX. All types are designed for mounting on the ceiling.
UP 258D41 - Presence Detector WIDE pro with temperature and relative humidity measurement
62%

Characteristics

  • These presence detectors are equipped with an integrated brightness sensor and HVAC sensors that use multiple calibration methods so that they can be adjusted at the particular installation location.
  • The maximum detection area is 64 m² for presence and 400 m² for motion.
  • The presence detectors capture brightness, humidity, temperature, brightness and CO2 and thus control not only the illumination systems but also ventilation and heating systems.
  • Communication is conducted via KNX. All types are designed for mounting on the ceiling.
UP 258D51 - Presence Detector WIDE multi with temperature, humidity and CO2 measurement
62%

Characteristics

  • These presence detectors are equipped with an integrated brightness sensor and HVAC sensors that use multiple calibration methods so that they can be adjusted at the particular installation location.
  • The maximum detection area is 64 m² for presence and 400 m² for motion.
  • The presence detectors capture brightness, humidity, temperature, brightness and CO2 and thus control not only the illumination systems but also ventilation and heating systems.
  • Communication is conducted via KNX. All types are designed for mounting on the ceiling.