DALI 4Net
17%

Overview

  • Independent light control of up to 256 DALI ballasts on 4 DALI-lines
  • Configuration via Ethernet and PCsoftware tool DALI Cockpit.
  • Modbus TCP access (control & visualisation).
  • With the DALI4Net control devices (input devices and sensors) and control devices on each DALI-line can be configured (Ethernet/DALI Interface).
  • Addressing, configuration, status queries, monitoring.
  • Collision detection.
  • DIN rail mounting.
  • 24V power supply (e.g. 24V/300mA Art.Nr. 24166012-24HS).
  • Basic version and standard version with additional central functions available.
DALI Repeater mit PS 200mA  DIN Rail
17%

Overview

  • Device to enhance the maximum DALI cable length from 300m up to 600m.
  • Enhancement and Transmission of the DALI-signals (bidirectional).
  • Galvanic separation between DALIcircuits.
  • Either radially arranged network layout or cascaded system mounting operated with single master.
  • Cascading (Series wiring) of up to 3 repeaters
  • The maximum amount of DALI-devices in the total network is limited to 64, the devices can be divided on the subcircuits freely.
  • For each subordinate DALI circuit, a separate bus power supply is needed. (DALI PS)
  • Type with integrated power supply available
  • Repeater PS: Test button for simple function check of all DALI bus ballasts.
  • Repeater PS: Module for DIN rail mounting and for remote ceiling installation available.
DALI Repeater DIN Rail
17%

Overview

  • Device to enhance the maximum DALI cable length from 300m up to 600m.
  • Enhancement and Transmission of the DALI-signals (bidirectional).
  • Galvanic separation between DALIcircuits.
  • Either radially arranged network layout or cascaded system mounting operated with single master.
  • Cascading (Series wiring) of up to 3 repeaters
  • The maximum amount of DALI-devices in the total network is limited to 64, the devices can be divided on the subcircuits freely.
  • For each subordinate DALI circuit, a separate bus power supply is needed. (DALI PS)
  • Type with integrated power supply available
  • Repeater PS: Test button for simple function check of all DALI bus ballasts.
  • Repeater PS: Module for DIN rail mounting and for remote ceiling installation available.
DALI Expander 3
17%

Overview

  •  Device for DALI-line expansion
  • Control of several DALI-devices via 3 DALI-addresses
  •  3 DALI outputs (DALI A,B,C) with integrated DALI power supply (50mA each) for powering control gear and control devices
  • For the superordinate DALI circuit the DALI expander acts like 3 separate DALI control gear – 3 DALI addresses, one for each subnet (A, B, C)
  • Forwarding commands received at the input (DALI IN) to the corresponding output (DALI A, B, C) broadcast
  • Alternative control options of the DALI-output circuits via Switch&Diminputs (Broadcast).
  • Group commands are passed from one to the other output circuits (cross function)
DALI-2 Expander HS
17%

Overview

• Device for simple DALI line expansion.

• Control of several DALI-devices via one DALI-address.

• For the superordinate DALI line the DALI Expander acts as a DALI EVG (DALI IN) with a single address.

• Output (DALI OUT) with DALI power supply (200mA) for the supply of DALI EVG's and DALI control modules.

• Forwarding commands received at the input (DALI IN) to the output (DALI OUT) broadcast.

• Alternative control options of the DALI-output line via Switch&Dim-input (Broadcast).

DALI-2 Expander S
17%

Overview

  • Device for DALI-line expansion
  • Control of several DALI-devices via 3 DALI-addresses
  • 3 DALI outputs (DALI A,B,C) with integrated DALI power supply (50mA each) for powering control gear and control devices
  • For the superordinate DALI circuit the DALI expander acts like 3 separate DALI control gear – 3 DALI addresses, one for each subnet (A, B, C)
  • Forwarding commands received at the input (DALI IN) to the corresponding output (DALI A, B, C) broadcast
  • Alternative control options of the DALI-output circuits via Switch&Diminputs (Broadcast).
  • Group commands are passed from one to the other output circuits (cross function)
  • Galvanic isolation between DALI-input and DALI-outputs
  • Independent control gear for remote ceiling an integration in luminaires
DALI PS24 100mA  Uin: 18-48V
17%

Overview

  • DALI bus power supply unit.
  • Guaranteed supply current 100mA.
  • Maximum supply current 130mA.
  • Suitable to power a DALI-line with up to 50 standard DALI ballasts.
  • Suitable for back box installation and integration in protection class II devices.
  • Power supply range 24Vdc … 48Vdc.
DALI PS2 80mA
17%

Overview

  • DALI bus power supply unit
  • Guaranteed Supply Current 30mA for Version 24033444-30, and. 80mA for Version 24033444-80
  • Maximum supply current allowed on a DALI line in total: 250mA
  • Version 24033444-30 is suitable to power a DALI-line with up to 15 standard DALI ballasts
  • Version 24033444-80 is suitable to power a DALI-line with up to 40 standard DALI ballasts
  • Suitable for back box installation and integration in protection class II devices
  • Power supply range 110Vac … 240Vac for worldwide use
  • Surge immunity up to 400V
DALI PS2 30mA
17%

Overview

  • DALI bus power supply unit
  • Guaranteed Supply Current 30mA for Version 24033444-30, and. 80mA for Version 24033444-80
  • Maximum supply current allowed on a DALI line in total: 250mA
  • Version 24033444-30 is suitable to power a DALI-line with up to 15 standard DALI ballasts
  • Version 24033444-80 is suitable to power a DALI-line with up to 40 standard DALI ballasts
  • Suitable for back box installation and integration in protection class II devices
  • Power supply range 110Vac … 240Vac for worldwide use
  • Surge immunity up to 400V
DALI PS128
17%

Overview

  • DALI bus power supply unit
  • Guaranteed Supply Current 128mA
  • Maximum Supply Current 250mA
  • Suitable to power an entire DALI-line with 64 standard DALI ballasts
  • Independent electronic device for remote ceiling and integration in protection class II devices
    power supply range 110Vac … 240Vac for worldwide use
  • Surge immunity up to 400V 
DALI PS2
17%

Overview

  • DALI bus power supply unit
  • Guaranteed Supply Current 200mA
  • Maximum Supply Current 250mA
  • Suitable to power an entire DALI-line with 64 standard DALI ballasts
  • Independent electronic device for remote ceiling and integration in protection class II devices
  • Power supply range 110Vac … 240Vac for worldwide use
  • Surge immunity up to 400V
DALI 2 PS
17%

Overview

  • DALI bus power supply unit
  • Guaranteed Supply Current 220mA
  • Maximum Supply Current 250mA
  • Suitable to power an entire DALI-line with 64 standard DALI ballasts
  • Suitable for DIN rail mounting
  • Power supply range 120Vac … 240Vac for worldwide use
  • Surge immunity up to 400V
  • Load indicator
  • Integrated test button for function check
  • System status queries (DALI current, bus load, runtime etc.) with DALICockpit Software
KNX Binary Input, 4 inputs / 4 outputs (LED)
50%
  • 4 fold inputs. Can be individually configured per input
  • 4 fold LED. Can be individually configured per LED
  • LED output current: max. 2.5mA, limited via series resistor of 2K Ohm
  • Input/Output wires: 2*5-pin wires, approx. 30cm. long. Can be extended up to 10 meters maximum
  • Size: 1.81 x 1.81 x 0.46 inches. Fits in a 1-gang US wall box
KNX Smart Touch Panel, 5 inches, Black, USA Frame
50%
  • Standard KNX device with database & certificate
  • 5" color capacitive IPS touch screen, resolution 480*854
  • 16 time functions, 8 event group functions, 8 logic functions
  • Password protection and customized screensaver
  • Support switching, dimming, shutter control, HVAC control and
  • other main KNX functions, built-in temperature sensor
  • Supporting ring included for installation, fits 60mm/86mm wallbox
  • The UI can be adjusted to accommodate both vertical and horizontal installation methods
  • Fits in 1-gang US Standard wall box
KNX Controller Touch & Pad, Metal, Black IPS capacitive touch panel & mechanical button
50%
  • IPS capacitive touch panel & mechanical button
  • Aluminum frame and replaceable buttons (plastic/aluminum)
  • Push Buttons adjustable for 1 or 2 button operation
  • Built-in temperature sensor, RGB status LED indication
  • Adjustable for button push length, NO or NC contact operation
  • Short/long operation for KNX functions of lighting, scene control, shutter etc
  • Fits in 1-gang US Standard wall box
Relay Module, 8 x 20A, 120/277VAC
62%
  • Rated voltage: AC 120 V
  • Rated current: 20 A
  • Number of channels: 8
  • Dimensions (W x H x D): 144 x 90 x 60 mm
  • Dimension width (1 MW = 18 mm): 8 MW
Analog Dimming Output, 8 x 1-10V, On/Off
62%
  • Outputs: Eight outputs (latching relays, potential-free contacts)
  • Electrical rating per output:ac/
    • 347 Vac, 50/60 Hz, 15A , cos phi = 1
    • 277 Vac, 50/60 Hz, 20A , cos phi = 1
    • 1.5 HP @ 120 Vac
    • 3 HP @ 277 Vac
  • Control voltage: 1 to 10V (provided by ECG Dynamic ballast)
  • Dimmable electronic ballast: Maximum 60 units
  • Signal amplifier: Maximum 12 units
Universal Dimmer 2-Fold
62%
  • Power supply: via KNX Bus line, 20VDC
  • Rated voltage: 120V AC +10%/-15%, 50/60 Hz
  • Rated current:
    • 2-channel: 2x1.3A@cosФ=1.0
    • 1-channel: 1x2.2A@cosФ=1.0
  • N-system DIN-rail mounted device, width:4MU(1MU=18mm)
  • Load output:
    Lamp type
    2 channels
    1 channel
    Incandescent lamps
    150 W
    250 W

    Low voltage halogen lamps

    with magnetic transformers

    120 VA
    200 VA
    Dimmable LED
    <= 50 VA
    <=50 VA
KNX/DALI Gateway Plus
62%
  • The KNX/DALI Gateway communicates with up to 64
  • DALI actuators per channel. These can be connected and dimmed in up to 16 groups per channel.
  • The gateway also supports selected sensors with DALI interface.
  • It also records and transfers DALI status and error messages.
  • An individual name, a group, parameter and scenes are assigned to individual DALI ECG´s during commissioning with the ETS (Engineering Tool Software).
  • DALI sensors and their functionality are also assigned in the ETS.
  • All DALI subscribers and functions are independent and can be linked via group addresses.
  • The device can only be operated in DALI segments with connected ECGs and sensors and not with further DALI controllers within the segment (no multi-master mode).
  • The power needed for ECGs and sensors is supplied directly through the gateway. An additional DALI power supply is not required, neither is it permitted.
KNX Power supply unit DC 29 V
62%
  • The device may be used for permanent interior installations in dry locations within distribution boards or small casings with DIN rail EN 60715-TH35. 
  • To ensure an uninterrupted power supply a separate circuit with safety separation should be used for the power supply unit power supply line.