{"product_id":"eelectron-sm03e03acc-plugin-sensor-for-pd00exxknx-co2-voc-temperature-white","title":"Eelectron SM03E03ACC PlugIn Sensor for PD00ExxKNX CO2, VOC, temperature – white","description":"\u003cp\u003eThe Eelectron SM03E03ACC is a plug-in indoor-air-quality sensor in white for the Eelectron presence detector range, with a true CO2 sensor (400–2000 ppm) plus VOC and temperature sensing. Clipped onto a PD00E02KNX Multi, PD00E03KNX Space, PD00E20KNX Wide Range or PD00E21KNX Corridor detector it turns the ceiling device into a complete demand-controlled-ventilation sensor for classrooms, meeting rooms, hotel rooms and open offices, with no extra bus device.\u003c\/p\u003e\n\u003cp\u003eThe module is powered and read through the host’s smart-sensor input and its front LED can be set to one of 4 modes to show CO2 bands (off ≤ 700 ppm, slow blink to 1000 ppm, fast blink to 1600 ppm, steady above) as a visible ventilation prompt for occupants. The VOC channel reports TVOC and needs approx. 96 hours to stabilise. Mount the sensor-plus-plug-in pair with the PD00E07ACC double squared ring, or in a PD00E00ACC surface enclosure. The black version is SM03E03ACC-3; the lighter SM03E02ACC offers VOC with eCO2 estimation only.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePlug-in for Eelectron presence detectors: PD00E02KNX (Multi), PD00E03KNX (Space), PD00E20KNX (Wide Range), PD00E21KNX (Corridor)\u003c\/li\u003e\n\u003cli\u003eCO2 sensor 400–2000 ppm, accuracy ±(50 ppm + 5 %)\u003c\/li\u003e\n\u003cli\u003eVOC sensor for Indoor Air Quality (TVOC)\u003c\/li\u003e\n\u003cli\u003eTemperature sensor, −5…+50 °C (23…122 °F)\u003c\/li\u003e\n\u003cli\u003eFront LED with 4 selectable modes indicating CO2 bands (700 \/ 1000 \/ 1600 ppm) or disabled; mode set by button\u003c\/li\u003e\n\u003cli\u003ePowered via the host sensor’s smart-sensor input: 12–24 V AC \/ 12–30 V DC, 6 mA, 50 mA peak\u003c\/li\u003e\n\u003cli\u003eAlso usable on the first input of the TC28A01KNX fan-coil controller\u003c\/li\u003e\n\u003cli\u003eVOC channel stabilisation approx. 96 h\u003c\/li\u003e\n\u003cli\u003eMounts with the detector via PD00E07ACC-1 \/ PD00E07ACC-3 double squared ring; surface enclosure PD00E00ACC or box frame PD00E01ACC\u003c\/li\u003e\n\u003cli\u003eFinish: white\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003ePlug-in sensor CO2 + VOC + temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e12–24 V AC \/ 12–30 V DC via the host sensor smart-sensor input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e6 mA; max. peak 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO2 sensor\u003c\/td\u003e\n\u003ctd\u003e400–2000 ppm; accuracy ±(50 ppm + 5 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVOC\u003c\/td\u003e\n\u003ctd\u003eTVOC measurement (IAQ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature sensor\u003c\/td\u003e\n\u003ctd\u003e−5…+50 °C (23…122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront LED\u003c\/td\u003e\n\u003ctd\u003e4 modes: CO2-band indication (≤700 \/ ≤1000 \/ ≤1600 \/ ≥1600 ppm), very-slow heartbeat, or always off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible hosts\u003c\/td\u003e\n\u003ctd\u003ePD00E02KNX(-3), PD00E03KNX(-3), PD00E20KNX(-3), PD00E21KNX(-3), TC28A01KNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStabilisation time\u003c\/td\u003e\n\u003ctd\u003eApprox. 96 h (VOC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor, dry locations; keep ≥ 4 mm from non-SELV (230 V) conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg (0.24 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer part no. \/ GTIN\u003c\/td\u003e\n\u003ctd\u003eSM03E03ACC \/ 8054144527802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eRelated Products\u003c\/h3\u003e\n\u003cp\u003eSM03E03ACC-3 (same plug-in in black). VOC + eCO2 + temperature version: SM03E02ACC \/ SM03E02ACC-3. Host detectors: PD00E02KNX \/ PD00E02KNX-3, PD00E03KNX \/ PD00E03KNX-3, PD00E20KNX \/ -3, PD00E21KNX \/ -3. Mounting: PD00E07ACC-1 \/ PD00E07ACC-3 double squared ring, PD00E00ACC \/ PD00E00ACC-3 surface enclosure, PD00E01ACC box frame.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCE certified; not UL\/NRTL listed — verify local code requirements before specifying in US installations.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0673\/4161\/5360\/files\/Eelectron_SM03E0xACCFI00010700_datasheet_A3-2_KNXSupply.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e · Available to order.\u003c\/p\u003e","brand":"Eelectron","offers":[{"title":"Default Title","offer_id":50559574278400,"sku":"SM03E03ACC","price":154.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/4161\/5360\/files\/20087533_01.jpg?v=1791483270","url":"https:\/\/www.knxsupply.com\/products\/eelectron-sm03e03acc-plugin-sensor-for-pd00exxknx-co2-voc-temperature-white","provider":"KNX Supply","version":"1.0","type":"link"}