{"product_id":"eelectron-hc06a01knx-1-knx-flush-mounted-temperature-controller-humidity-white","title":"Eelectron HC06A01KNX-1 KNX flush-mounted temperature controller humidity – white","description":"\u003cp\u003eThe Eelectron HC06A01KNX-1 is the flush-mounted 9025 humidity-temperature controller HC06A01KNX in white: temperature and humidity sensing, six capacitive keys and two independent two-stage thermostats in a 2-module wall device with no display. It is finished with the matching 9025GH06L01 glass (ordered separately) and is the room controller for spaces where air quality and climate are managed from one point — hotel rooms, classrooms, meeting rooms, offices and apartments.\u003c\/p\u003e\n\u003cp\u003eThe two thermostats each have an integrated PI controller for heating and cooling with valves, 6-way valves and 2- or 4-pipe fan coils, and can serve two zones. The humidity sensor drives threshold-with-hysteresis control of humidifiers and dehumidifiers. A rear 2-pole input takes a dry contact or an external NTC probe for a second temperature point.\u003c\/p\u003e\n\u003cp\u003eThe six capacitive keys are configured in ETS for on\/off, dimming, shutters and blinds, scenes, sequences and local thermostat commands; the front RGB LED shows temperature, humidity or any other bus value. It mounts on an Italian 2-module, German or British box and includes the KNX bus coupler.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo sensors on board: temperature and relative humidity\u003c\/li\u003e\n\u003cli\u003eTwo independent two-stage thermostats with PI controllers — heating, cooling, valves, 6-way valves, 2- and 4-pipe fan coils\u003c\/li\u003e\n\u003cli\u003eHumidity control: humidification \/ dehumidification by thresholds with hysteresis\u003c\/li\u003e\n\u003cli\u003e6 capacitive keys for lighting, shading, scenes, sequences and local climate control\u003c\/li\u003e\n\u003cli\u003eFront RGB LED for status (temperature, humidity) or any KNX value\u003c\/li\u003e\n\u003cli\u003eRear 2-pole input: dry contact (≤10 m) or NTC probe TS01A01ACC \/ TS01B01ACC \/ TS01C01ACC \/ TS01D01ACC (≤30 m)\u003c\/li\u003e\n\u003cli\u003eTemperature -5 to +55 °C, 0.01 °C resolution, ±0.5 °C typ.; humidity 0–100 %RH, 0.1 %RH resolution, ±2 %RH typ.\u003c\/li\u003e\n\u003cli\u003eBus powered: 15 mA @ 24 V\u003c\/li\u003e\n\u003cli\u003e2-module format 96 x 96 x 36 mm; Italian, German and British boxes; bus coupler included\u003c\/li\u003e\n\u003cli\u003e250 group addresses \/ 250 associations; KNX certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eVia KNX bus, 23–32 V DC (SELV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e15 mA @ 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensors\u003c\/td\u003e\n\u003ctd\u003etemperature, humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature sensor\u003c\/td\u003e\n\u003ctd\u003e-5 to +55 °C (23 to 131 °F), resolution 0.01 °C, tolerance ±0.5 °C typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity sensor\u003c\/td\u003e\n\u003ctd\u003e0–100 %RH, resolution 0.1 %RH, tolerance ±2 %RH typ. (±3 %RH max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeys\u003c\/td\u003e\n\u003ctd\u003e6 capacitive keys + front RGB LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostats\u003c\/td\u003e\n\u003ctd\u003e2 x two-stage with PI controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear input – digital\u003c\/td\u003e\n\u003ctd\u003edry contact, scanning 3.3 V DC, cable ≤10 m (33 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRear input – analog\u003c\/td\u003e\n\u003ctd\u003eNTC probe TS01A01ACC \/ TS01B01ACC \/ TS01C01ACC \/ TS01D01ACC, cable ≤30 m (98 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup addresses \/ associations\u003c\/td\u003e\n\u003ctd\u003e250 \/ 250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e2-module flush box: Italian 502, German, British\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ePC-ABS, IP20 (EN 60529), pollution degree 2, safety class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e96 x 96 x 36 mm (3.78 x 3.78 x 1.42 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to +45 °C (23 to 113 °F); storage -20 to +55 °C; RH max 85% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapprox. 130 g without glass, 240 g with glass; packed 0.13 kg (0.29 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 63044-3, EN 63044-5-1, EN 63044-5-2, EN 50491-2; LVD 2014\/35\/EU, EMC 2014\/30\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eKNX certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eETS application\u003c\/td\u003e\n\u003ctd\u003eEelectron ETS application (download from eelectron.com)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer part no. \/ GTIN\u003c\/td\u003e\n\u003ctd\u003eHC06A01KNX-1 \/ 8054144521183\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eRelated Products\u003c\/h3\u003e\n\u003cp\u003eRequired glass: 9025GH06L01 (white). Other colour: HC06A01KNX-3. Version with CO2 sensor: MC06A01KNX-1 \/ -3. NTC probes: TS01A01ACC, TS01B01ACC, TS01C01ACC, TS01D01ACC; TS01D01ACC glass 9025GS00A01 \/ 9025GS00A03. 9025 push buttons for the same wall: CS10A01KNX-1 with 9025GL glass covers.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCE certified; not UL\/NRTL listed — verify local code requirements before specifying in US installations.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0673\/4161\/5360\/files\/Eelectron_GTxxAxxKNXFI00010104_datasheet_KNXSupply.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet (PDF)\u003c\/a\u003e · Available to order.\u003c\/p\u003e","brand":"Eelectron","offers":[{"title":"Default Title","offer_id":50560340885760,"sku":"HC06A01KNX-1","price":173.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0673\/4161\/5360\/files\/HC_Hardware_white-3.jpg?v=1791483800","url":"https:\/\/www.knxsupply.com\/products\/eelectron-hc06a01knx-1-knx-flush-mounted-temperature-controller-humidity-white","provider":"KNX Supply","version":"1.0","type":"link"}